Author | Message |
---|---|
Topic: WRT320N, Extra Cooling/Heat Sink, Case Mod | |
ev1te Replies: 18 Views: 47324 |
Forum: Hardware DIY / Hardware Mods Posted: Thu Feb 11, 2010 22:59 Subject: WRT320N, Extra Cooling/Heat Sink, Case Mod |
Just a small update, I have been running the router on 480/240 Mhz for several weeks now, without any reboots or instabilities. | |
Topic: K2.6 Increase Maximum Connections ip_conntrack_max hashsize | |
ev1te Replies: 29 Views: 81723 |
Forum: Broadcom SoC based Hardware Posted: Wed Feb 10, 2010 20:28 Subject: K2.6 Increase Maximum Connections ip_conntrack_max hashsize |
OK, got it working, without the broken ui! 1) In order for the UI to pick up the max connection increase, one must use 'nvram set' (at least on the rt-n16), although I suspect that setting the proc v ... |
|
Topic: K2.6 Increase Maximum Connections ip_conntrack_max hashsize | |
ev1te Replies: 29 Views: 81723 |
Forum: Broadcom SoC based Hardware Posted: Mon Feb 08, 2010 9:30 Subject: K2.6 Increase Maximum Connections ip_conntrack_max hashsize |
Sorry for the misunderstanding, I must have mixed up the v24 with K24. I am using a nvram value of 16384 for ip_conntrak_max. My startup script begins a "sleep" in order for all th ... |
|
Topic: K2.6 Increase Maximum Connections ip_conntrack_max hashsize | |
ev1te Replies: 29 Views: 81723 |
Forum: Broadcom SoC based Hardware Posted: Sun Feb 07, 2010 21:49 Subject: K2.6 Increase Maximum Connections ip_conntrack_max hashsize |
I have the same problem as Nolar, running DD-WRT v24-sp2 (01/02/10) big - build 13575M NEWD-2 K2.6 Eko. RT-N16, nvram set ip_conntrack_max=16384 nvram commit reboot Run: echo "16384" ... |
|
Topic: K2.6 Increase Maximum Connections ip_conntrack_max hashsize | |
ev1te Replies: 29 Views: 81723 |
Forum: Broadcom SoC based Hardware Posted: Sun Feb 07, 2010 16:12 Subject: K2.6 Increase Maximum Connections ip_conntrack_max hashsize |
I am using 2.6 (you have 2.4) which might explain a few things. From what i understand you can not only increase the ip_conntrack_max value in linux, you also have to increase the hash table for thes ... |
|
Topic: push "redirect-gateway def1" | |
ev1te Replies: 3 Views: 10414 |
Forum: General Questions Posted: Sat Jan 30, 2010 15:52 Subject: push "redirect-gateway def1" |
I have only used redirect-gateway def1 with OpenVPN in bridged mode. Make sure the clients have the routers LAN address as the default gateway (push "route-gateway xxx" or server directive) ... |
|
Topic: K2.6 Increase Maximum Connections ip_conntrack_max hashsize | |
ev1te Replies: 29 Views: 81723 |
Forum: Broadcom SoC based Hardware Posted: Sat Jan 30, 2010 12:59 Subject: K2.6 Increase Maximum Connections ip_conntrack_max hashsize |
I have seen several people before, that have had problems with the maximum number of connections becoming reached... But there hasn't been any response to this solution that I came up with for the K2 ... |
|
Topic: WRT320N, Extra Cooling/Heat Sink, Case Mod | |
ev1te Replies: 18 Views: 47324 |
Forum: Hardware DIY / Hardware Mods Posted: Fri Jan 29, 2010 23:41 Subject: WRT320N, Extra Cooling/Heat Sink, Case Mod |
I have experienced some random reboots since I overclocked it to 480.. temporarily I downclocked to 400,200 since I will be going away for a couple of days and need the router (OpenVPN etc.) to be ope ... | |
Topic: OpenVPN Site Bridge. Clients get IP from wrong network | |
ev1te Replies: 35 Views: 29375 |
Forum: Broadcom SoC based Hardware Posted: Fri Jan 29, 2010 21:45 Subject: OpenVPN Site Bridge. Clients get IP from wrong network |
Maybe I shouldn't make it so complicated for myself, it's not for a corporate solution or anything, just to simplify my own private network withe some friends. :) You could block the offensive clie ... |
|
Topic: OpenVPN Site Bridge. Clients get IP from wrong network | |
ev1te Replies: 35 Views: 29375 |
Forum: Broadcom SoC based Hardware Posted: Thu Jan 28, 2010 23:18 Subject: OpenVPN Site Bridge. Clients get IP from wrong network |
So now I have removed ebtables completely, and are looking for another solutions (or a faster router) The other solutions are to either use a routed tunnel instead of a bridged one, or to only run ... |
|
Topic: WRT320N, Extra Cooling/Heat Sink, Case Mod | |
ev1te Replies: 18 Views: 47324 |
Forum: Hardware DIY / Hardware Mods Posted: Wed Jan 27, 2010 19:37 Subject: WRT320N, Extra Cooling/Heat Sink, Case Mod |
I have experienced some random reboots since I overclocked it to 480.. temporarily I downclocked to 400,200 since I will be going away for a couple of days and need the router (OpenVPN etc.) to be ope ... | |
Topic: OpenVPN Site Bridge. Clients get IP from wrong network | |
ev1te Replies: 35 Views: 29375 |
Forum: Broadcom SoC based Hardware Posted: Wed Jan 27, 2010 19:03 Subject: OpenVPN Site Bridge. Clients get IP from wrong network |
Thanks for the explanation, I have some understanding of iptables, but not when it comes to postrouting and masquerade. Does anyone know an application for simulating broadcast packets (manually send ... |
|
Topic: WRT320N, Extra Cooling/Heat Sink, Case Mod | |
ev1te Replies: 18 Views: 47324 |
Forum: Hardware DIY / Hardware Mods Posted: Wed Jan 27, 2010 11:38 Subject: WRT320N, Extra Cooling/Heat Sink, Case Mod |
Setting the WRT320N too 453/226 will also send it to 480/240. You'll end up with the same clock speed. I've been running 480/240/120 here for quite some time with no extra heatsink (also stressed it ... | |
Topic: OpenVPN Site Bridge. Clients get IP from wrong network | |
ev1te Replies: 35 Views: 29375 |
Forum: Broadcom SoC based Hardware Posted: Tue Jan 26, 2010 15:54 Subject: OpenVPN Site Bridge. Clients get IP from wrong network |
Also could someone please explain in detail what this line actually does? (I don't like adding lines in my iptables without knowing what they do ) : iptables -t nat -D POSTROUTING -o br0 -s $LAN_NE ... |
|
Topic: WRT320N, Extra Cooling/Heat Sink, Case Mod | |
ev1te Replies: 18 Views: 47324 |
Forum: Hardware DIY / Hardware Mods Posted: Tue Jan 26, 2010 15:17 Subject: WRT320N, Extra Cooling/Heat Sink, Case Mod |
I added the Black heatsink today and are now running clkfreq=480,240,120. The heatsink is approx. 50-60 degrees Celsius by touch (need new batterys to my IR-thermometer) I used a very small amount of ... |
|
All times are GMT |